2 electrical data, Electrical data – Baumer ATD 2S B14 Y24 Benutzerhandbuch
Seite 23
Advertising
Technical data
Baumer_ATD2SB14Y24_II_DE-EN_1309.indd
23
10.2
Electrical data
Voltage supply
10...30 VDC
Reverse polarity protection
Yes
Consumption w/o load
≤60 mA (24 VDC)
Interface
SSI
Function
Multiturn
Steps per turn
4096 / 12 bit
Number of turns
4096 / 12 bit
Sensing method
Magnetic
Code
Gray or binary
Code sequence
CW: ascending values with clockwise sense of
rotation (looking at mounting surface)
Inputs
SSI clock
Reset input
Output circuit
SSI data: linedriver RS485
Diagnostic output: error
Interference immunity
DIN EN 61000-6-2
Emitted interference
DIN EN 55011
Diagnostic function
Self-diagnosis
Number of pole pairs
1 = 2 poles
Input voltage
7 Vrms
Input frequency
≤10 kHz
Transformation ratio
0.5 ±5 %
Phase shift
0° ±10°
Electr. errors max.
±10 Angular minutes