Power-ON Utilities
There are three power-ON utilities to set up and test printer hardware. These
utilities are activated by pressing the FEED button ( ) then turning on the printer
power ( ) simultaneously and release the button at different LED light
indications.
Power-ON Utility for standard panel
Follow the steps below for different power-on utilities.
1.
Turn off the printer power switch.
2.
Press down the FEED button ( ) then turn on the power switch (
).
3.
Release the power switch (
) when LED color turns to amber,
continue pressing the FEED button.
4.
The printer will beep twice, then release the FEED ( ) button when the
battery LED indicates the desired function:
Media sensor calibration
Follow the steps below to calibrate the media sensor.
1.
Turn off the printer power switch.
2.
Hold on the FEED button ( ) then turn on the power switch (
).
3.
Release the power switch (
) when LED color turn on amber,
continue pressing the FEED button.
4.
The printer will beep twice, then release the FEED ( ) button when the
battery LED indicates and blinking. The LED will sequence right
to left, 5 blinks each.
5.
The printer will calibrate the sensor and print out the internal settings,
then enter the DUMP mode. Turn the printer OFF/ON to exit DUMP
mode.
(No LCD Display)
Printer initialization
Media sensor
calibration, self- test
and enter DUMP
Mode
Media sensor
calibration
Release FEED
button for
different functions
LED
(5 blinks)
(5 blinks)
(5 blinks)
Power ON Utilities
Standard Panel
Battery LED Configurations