Sensor – AMT Datasouth Fastmark M4 Benutzerhandbuch
Seite 48

~ 48 ~
Sensor
Main
Menu
Setup
Sensor
Auto Calibration
Manual Setup
Threshold
Max. Length
Advanced
Min. Paper
Max. Gap/Mark
Gap
Black Mark
Continuous
Gap
Black Mark
Continuous
Auto
Fixed
ON
OFF
Scan Backing
Scan Mark
Label
Scan
Paper
Scan
Paper
Paper
Item
Description
Default
Auto
Calibration
This feature is used to set the media sensor type and
calibrate the selected sensor. The printer will feed 2 to 3
gap labels to calibrate the sensor sensitivity
automatically.
N/A
Manual Setup
This feature is used to manually set media sensing
(Gap, Black Mark and Continuous) and material type
(label backing and paper).
N/A
Threshold
This feature is used to fix the calibrated sensor
sensitivity.
Auto
Maximum
Length
This feature is used to set the max. calibration length.
152
Advanced
This feature is used for pre-printed paper. If this
advanced function is turned “ON” then you can setup the
min. paper and max. gap/black mark size
OFF