EverFocus EKR-KB1 Benutzerhandbuch

Seite 93

Advertising
background image

Page 91

MNNCEKRKB1_0439

6.13 Pelco Dom e

6.13.1 Reference m aterial and documents

Dome Spectra II 3.31
Pelco Protocol Manual, “D” Protocol, March 2, 1999

6.13.2 Connection

6.13.2.1 Cable

White

Yellow

RS485A

RS485B

RX+

RX-

6.13.2.2 Dome setting s

Dome ID-number must be set according to the respective installation manual.
Protocol must be set as Type ‘D’.

6.13.2.3 Keyboard set tings

During Keyboard setup, submenu



must be suitably set:









Baudrate is fixed (2400 baud).

6.13.3 Setup

The dome can be set up by pressing a combination of keys or by inserting a special code.
For all setup operations the keyboard must be enabled to perform the receiver setup (menu



).

6.13.4 Preset, sca n, home



(1÷32): store the present position as preset position number X



(1÷32): erase previously stored preset position number X



(1÷32): movement towards previously stored position X

: movement towards the Home position, corresponding to preset position 1



: movement towards pan position 0