14 samsung dome – EverFocus EKR-KB1 Benutzerhandbuch

Seite 96

Advertising
background image

Page 94

MNNCEKRKB1_0439

6.14 Samsung Dome

6.14.1 Reference m aterial and documents

Dome Samsung SCC-641
Dome Samsung SCC-643P
Samsung Protocol

6.14.2 Connection

6.14.2.1 Cable

White

Yellow

White

Yellow

SCC-641

RS485A

RS485B

SCC-643

RS485A

RS485B

Txd +

Txd -

Rxd +

Rxd –

6.14.2.2 Dome setting s

Dome ID-number must be set according to the respective installation manual.
Baudrate can be selected among the following values: 4800, 9600 (default), 19200, 38400 baud.
For the Dome SCC-643 configure the mode FULL DUPLEX. Should the system require it, there can be
configured the mode HALF DUPLEX: in this case the connection is the same as for the Dome SCC-641, on the
poles Txd+ and Txd-.

6.14.2.3 Keyboard set tings

During Keyboard setup, submenu



, must be suitably set:









Baudrate must be equal to the one selected for the dome.

6.14.3 Setup

Dome setup is mostly carried out by On Screen Menu.
Some parameters can be set up by pressing a combination of keys or by inserting a special code.
For all setup operations the keyboard must be enabled to perform the receiver setup (menu



).