Note:

The measuring values of “measurement color bar” or “measurement online
trend” are automatically saved as "standard.i12". Should you need to edit the
data later, you need to save the file as another .i12-file because old values are
over-written when a new measurement is taken.

Files from older program versions (.i10-files) can be opened and saved as .i12.


10.10 Output listing (analyzing)

For reconsider the measured values in
this field all measured data appears in a
numeric list.

The date beside the time gives more exactly
values to see what happened on time units
smaller 1 s. The value specifies the time in sec-
onds after midnight (0:00 h). The amount of data
depends on the frequency that readings were
taken (settings at 10.13 PC sampling rate) as
the amount of data increases, so does the
amount of storage space required to save it. In
order to save room, all .i12 data files are stored
by a binary code.



10.11 Trend output (analyzing)

The graph’s curve depicts the tem-
perature change over time within
the specified temperature range.

Additionally, other information appears in
this window; such as recorded time (x-axis)
and temperature in degrees (y-axis) as well
as the time and temperature at the vertical
cursor line which can be dragged with the
mouse.
Selecting the Trend output initially causes
all the saved data to be displayed.
If the data exceeds an amount that can be
represented reasonably, you may “Zoom“ in
on a partial segment using the mouse (such
as the segment represented in the example).
Under “Total” you can return to the represen-
tation of the entire curve.

Note:

The last reading is saved in the standard.i12 file and automatically appears in
this form upon opening Listing or Trend output.
If file open was loaded using another file, the previous file will be overwritten and
replaced by the standard.i12 file.



10.12 Output .TXT file (analyzing)

The same file as under „Output listing” may be converted into a text file and can be easily opened,
for example with EXCEL. EXCEL will automatically correctly format the columns with the default
import settings (tab as separator).