15 reference numbers, 1 reference numbers of instruments, Reference numbers – LumaSense Technologies ISR 12-LO Benutzerhandbuch

Seite 27: Reference numbers of instruments, Tion 15

Advertising
background image

IMPAC pyrometers ISR 12-LO · IGAR 12-LO

26

Reading parameters:

AApa

Output decimal 11-digit:

Digit 1 und 2 (10...99 or 00): (emissivity)

Digit 3 (0 ... 6): t

90

(exposure time)

Digit 4 (0 ... 8): t

CL

(clear time of max. storage)

Digit 5 (0 ... 1): analog output

Digit 6 und 7: (00 ... 98): pyrometer’s temperature

Digit 8 und 9 (00 ... 97): address

Digit 10 (0 ... 6 or 8): baud rate

Digit 11 (0): (0 or 1): keyboard active or locked

Digit 12 ... 15 (0800 ... 1200): emissivity slope

Autoreset:

AAre

Activating auto-reset, initializes the pyrometer new and

resets the instrument to default settings

Reference number:

AAbn

Output: XXXXXX (hex 6-digit)

Serial number:

AAsn

Output: XXXXX (5-digit, decimal)

Device type /
software version:

AAve

Output: XXYYZZ (6-digit, decimal)
XX = 63 (ISR 12-LO or IGAR 12-LO)
YY = month of software version
ZZ = year of software version

Software version
in detail:

AAvs

tt.mm.yy XX.YY
tt = day; mm = month; yy = year; XX.YY = software version

Device type:

AAna

Output: “ISR 12-LO“ or “IGAR 12-LO (16 ASCII-characters)

Note: the letter “l” means the lower case letter of “L”.


15

Reference numbers


15.1

Reference numbers of instruments


3 855 100

ISR 12-LO

MB 13:

600 ... 1300°C

3 855 110

ISR 12-LO

MB 18:

750 ... 1800°C

3 855 120

ISR 12-LO

MB 25:

900 ... 2500°C

3 855 130

ISR 12-LO

MB 33:

1000 ... 3300°C

3 855 200

IGAR 12-LO MB 10:

300 ... 1000°C

3 855 210

IGAR 12-LO MB 13:

350 ... 1300°C

3 855 220

IGAR 12-LO MB 22:

500 ... 2200°C



Scope of delivery:
Converter, fiber optic, length 2.5 m, optical head I or II, PC software InfraWin, work certificate, user manual.
Note: a connection cable is not included in scope of delivery and has to be ordered separately.


Ordering details:
To process your order as fast as possible, please give us the following data:
Instrument with reference number (e.g. ISR 12-LO; 3 855 100)
Optical head’s design (I or II) and the desired measuring distance (e.g. optical head I, a = 120 mm)
Length of optical fiber (except standard length 2.5 m)
Connecting cable (e.g. 5 m length 3 820 330)