Connection with the automation system

The communication with the target system (controller, Drive PLC, etc.) requires a fieldbus-specific

interface module for the PC and the corresponding fieldbus modules for the drives to be connected.
The following table gives an overview of the transfer media which are included in the basic DriveServer

package.

Bus system

PC port

Max. number

of

automation

systems

Required

hardware components

Required

software components

System bus

(CANopen)

Parallel port

(LPT port)

63

PC system bus adapter 2173

incl. connection cable and

voltage supply adapter

for DIN keyboard connection

(EMF2173IB)

for PS/2 keyboard connection

(EMF2173IBV002)

for PS/2 keyboard connection

with electrical isolation
(EMF2173IBV003)

Bus server for system bus

(part of the DriveServer
package)

USB

( Universal

Serial Bus)

PC system bus adapter 2177

incl. connection cable

(EMF2177IB)

LECOM

Serial port

(COM port)

1
(RS232)

Fieldbus module EMF 2102IB

V001 or V004

Bus server for LECOM

(part of the DriveServer

(COM port)

(RS232)

V001 or V004

PC system cable RS232/485,
5m (EWL0020)

(part of the DriveServer

package)

31
(RS485)

Fieldbus module EMF 2102IB

V001

PC system cable RS232/485,
5m (EWL0020)

Interface converter

RS232/RS485 with automatic

change of direction*

52
(optical fibre)

Fieldbus module EMF 2102IB

V003

Optical fibre adapter
(EMF2125IB)

Power supply for adapter

(EJ0013)

Optical fibre cable (EWZ0007)

* not available at Lenze; for list of suppliers please see the online documentation (