HK Audio FirSoft Benutzerhandbuch

Seite 10

Advertising
background image

FirSoft 1.0

10

In EQ 1 & In EQ 2

All group members can be equalized collectively using fully parametric IIR filters for the inputs. You
have Peak, Hi and Low Pass, Hi and Low Shelf filters at your disposal. Each filter may be switched
on and off individually.

Heads up: Only master groups have active filters by default. You must manually add filters from
devices‘ library for any other group that needs filters. This is done by right-clicking the filters‘
graphical representation and then clicking ADD FILTER in the context menu. One fully parametric
filter is added at a time.

If these filters are not required in groups, they can be removed in the same way as described above,
although using REMOVE FILTER rather than ADD FILTER. The most recently added filter is deleted
first.

HEADS UP: No more than 12 fully parametric IIR filters may be used per device and input.

Device View

The main window:

This panel provides information on the device‘s setup, the parameters of which may only be edited
in the Setup panel. It also shows input and output levels, input and output gain levels, delays, the
delay unit, mute and phase reversal statuses, and maps out how the 2 inputs are routed to outputs
1 to 4.