HK Audio FirSoft Benutzerhandbuch

Seite 11

Advertising
background image

FirSoft 1.0

11

The Setup panel:

The SETUP panel serves to configure signal inputs and calibrate AD and DA converters.

FIRSOFT also provides a sinusoidal signal generator that you can use to route test tones to the
FIRNET controller‘s four outputs. You can set the gain level and frequency as you see fit.

Heads up: Be sure to set the MAX. AD OUT parameter so that it matches the given amplifier

model‘s voltage gain. The FIRNET controller‘s limiters may not operate properly if these

settings do not match, and speakers may be damaged!

The Out EQ A to Out EQ D panel:

The OUT A – OUT D panel serves to process the six fully parametric filters that are available at each
output of the device. You have Peak, Hi and Low Pass, Hi and Low Shelf filters at your disposal.
Each filter may be switched on and off individually.