Control board diagrams, 240 v csa and 230 v ce, Steuerbaukarten-diagramme – Hypertherm Powermax45 Rev.1 Benutzerhandbuch

Seite 132: Schaltpläne 8-2 powermax, Control pwa, Wartungshandbuch

Advertising
background image

Schaltpläne

8-2

Powermax

45

Wartungshandbuch

FAULT

YEL

AMPS

CW

CAPOFF

YEL

"TSO/TSC"

AC PWR

GRN

"L/H LINE"

720

IN

15

IN

9

V-

8

IN

7

IN

13

IN

12

IN

11

IN

10

IN

6

V+

16

IN

3

IN

2

IN

1

IN

5

IN

14

IN

4

JTAG

1

3
5
7
9

11
13

14

2
4
6
8

10
12

1 2

3 4
5 6
7 8
9 10

11 12
13 14
15 16
17 18
19 20

21 22
23 24
25 26

2

1

3

4 5

6

7

ON

ON CASE

CASE

1

2
3
4

TEMP

YEL

L

R

1

ERROR

CODE

.25"

FOR

BD

DEPAN-

IZATION

SERIAL

DATA

MACHINE

FRONT

DSP 2806

4x25Mhz=100Mhz

0.78 x 0.78"

Stayout for

TEST CLIP

/RESET or

HDR FLT

START

XFR

GAS

CONTROL PWA

CPA (UP)
NORMAL (MIDDLE)
GOUGE (DOWN)

YEL

YEL

GRN

"SETPOINT"

GRN

GRN

MODE

45 A 230 V

Steuerbaukarten-Diagramme

200–240 V cSa und 230 V ce

J7 Stiftnummer an Masse

test

erwarteter Wert

(200–240 V cSa oder 230 V ce)

19

VACR (gleichgerichtete  

AC-Netzspannung)

1,95 V bei 230 V Netzspannung

21

VBUS (DC-Busspannung)

2,28 VDC bei 385 VBUS

18 

(nur 200–240 und 230 V)

IPFC (Netzstrom)

< 0,1 VDC

20

IFB (Ausgangsstrom)

< 0,1 VDC

22

ITF (Übertragungsstrom)

< 0,1 VDC

25

3,3 VDC

3,3 VDC ± 5 %

24

5 VDC

5 VDC ± 5 %

12

24 V Messstift

2,2 VDC

16

Startsignal

3,2 VDC geschlossen

0 VDC offen