47

OBJECT DET

Alarm is activated when an object disappears or appears in user-defined area.
• You can set OD Window for the detection range of 3(H) x 3(V) in 9 blocks.
• When the motion is detected in the set frame, the Alarm activates through Alarm ACK and
OD-Out port.
• You can set the Zoom position (OD Zoom Preset) to move when the OD Alarm is activated.
• The interval of dwell time can be set up to 56 seconds in units of one second.

Dwell Time: It keeps the OD Alarm Signal (OD-Out) and OD Zoom Preset Position during the

set dwell time, after the alarm activated.

MODE: Object detection enable or disable OFF/ON
AREA#:
Select OD Area number (~9)
SENSITIVITY: Adjust sensitivity (~5)
DEWELL TIME: Select the duration time about changing OD mode (~56sec)
ZOOM PRESET: Select zoom position to move when alarm is occurred