Design and function – WIKA TR31 Benutzerhandbuch

Seite 14

Advertising
background image

GB

14096788.01 07/2014 GB/D

14

WIKA operating instructions models TR31-3, TR31-K

CE conformity, approvals,

patents/property rights

CE conformity

EMC directive

12)

2004/108/EC, EN 61326 emission

(group 1, class B) and interference

immunity (industrial application)

Approvals

IECEx

Ignition protection type “i” - intrinsic

safety, ignition protection type “iD” -

dust protection through intrinsic safety

Patents/property rights

M12 x 1 adapter to angular

connector DIN EN 175301-803

Property right registered under

No. 001370985

12) Only for built-in transmitter

For further specifications see WIKA data sheet TE 60.31 and the order

documentation.

4. Design and function

4.1 Description

The model TR31 resistance thermometer consists of a thermowell with

a fixed process connection and is screwed directly into the process.

It is designed to be impact and vibration resistant and all electrical

components are protected against humidity (IP 67 or IP 69K). The

vibration resistance conforms to IEC 60751 (20 g, dependent on the

instrument version). The impact resistance of all versions meets the

requirements of IEC 60751. The electrical connection is made via an

M12 x 1 circular connector or via the directly connected cable.

An adapter for electrical connection with angular connector per

DIN EN 175301-803 is optionally available for the M12 x 1 circular

connector version.

4. Design and function

Advertising