WIKA operating instructions models TR31-3, TR31-K

6.2 Electrical connection

The electrical connection is made via a circular connector.

M12 x 1, 4-pin circular connector

Pin Signal Description

1

L+

10 ... 30 V

2

VQ

not connected

3

L-

0 V

4

C

not connected

Pt100 and Pt1000 output signal

4 ... 20 mA output signal

6. Commissioning, operation

Directly connected cable

Wire

Signal Description

brown

L+

10 ... 30 V

blue

L-

0 V

Pt100 and Pt1000 output signal

4 ... 20 mA output signal

2-wire

red

white

white

white

white

red

red

red

red

3-wire

4-wire

brown

blue

Advertising