Specifications / 4. design and function, Design and function – WIKA TR33 Benutzerhandbuch

Seite 13

Advertising
background image

GB

WIKA operating instructions model TR33

14073818.01 01/2014 GB/D

13

Ambient conditions

Ambient and storage

temperature range

-40 ... +85 °C (-40 ... +185 °F)

Climate class per IEC 60654-1

Cx (-40 ... +85 °C or -40 ... +185 °F,

5 ... 95 % relative air humidity)

Maximum permissible humidity

per IEC 60068-2-30 var. 2

relative humidity 100 %,

condensation allowed

Vibration per IEC 60751

10 ... 2,000 Hz, 20 g

1)

(Amplitude)

Shock

IEC 60068-2-27

Salt fog

IEC 60068-2-11

Electromagnetic compatibility

(EMC)

2004/108/EC, EN 61326 emission

(group 1, class B) and interference

immunity (industrial application)

1) Dependent on the instrument version

For further specifications see WIKA data sheet TE 60.33 and the order

documentation.

4. Design and function

4.1 Description

The model TR33 resistance thermometer consists of a thermowell with

a fixed process connection and is screwed directly into the process.

It is designed to be impact and vibration resistant and all electrical

components are protected against humidity (IP 67 or IP 69K). The

vibration resistance conforms to IEC 60751 (20 g, dependent on the

instrument version). The impact resistance of all versions meets the

requirements of IEC 60751. The electrical connection is made via an

M12 x 1 circular connector.

An adapter for electrical connection with angular connector per

DIN EN 175301-803 is optionally available.

3. Specifications / 4. Design and function

Advertising