20

8 Functions and operation

Setting the limits (limit comparators)

You can alter both limits by using the “Span” and “Zero” buttons.
The momentary value is produced via the output. The value is
accepted by simultaneously pressing “Span” and “Zero”.

“Span” and “Zero” can always be used to set the limits. However,
the limit query can only be activated through the PC setup program,
which is available as an extra. There you can also define the limits
for the differential.

Two functions are available for limit monitoring. You can decide
which one to use by means of the PC setup program.

Function lk7:

Function lk8: