5 software configuration, 1 dcom configuration, Dcom configuration – Lenze DriveServer Erste Schritte Benutzerhandbuch
Seite 46: 5software configuration, Driveserver

DriveServer
L
44
DriveServer DE/EN 1.1
5
Software configuration
One of the main objectives of the DriveServer is to reduce the configuration of the system to a minimum
(Plug and Drive). Unfortunately it is not possible to completely do without a configuration.
The following describes the configuration of DCOM and the bus server for LECOM and system bus. If
you use different bus servers, the configuration must be obtained from the corresponding Instructions.
Note!
Ensure that the drives connected to the bus have different addresses before the configuration of the
bus server. For this, it may be necessary to individually connect the drives to the bus system and
configure them accordingly. Alternatively, the address of a drive can be changed using the keypad.
5.1
DCOM configuration
Note!
With Windows 98 it is not necessary to configure DCOM if the communication is not required between
several PCs.
The OPC standard enables the user, for instance, to access DriveServer data on a local network. To
protect from unauthorized access, the safety standards do not allow OPC access. These settings must
therefore be check and changed, if necessary, before commissioning the DriveServer.
The easiest is to adapt the standard parameters. They apply to all servers installed on the PC. Individual
DCOM configuration for single servers is only required for special applications.
Information about
•
Settings for OPC server and OPC client(s) can be found in chapter 5.1.1
(
•
Settings which only apply to the OPC server can be found in chapter 5.1.2
(
Note!
The settings described in the following should be agreed by a system’s administrator because they have
an influence on the safety checks to ensure easy commissioning of the DriveServer.
Show/Hide Bookmarks