1. Select
Run... from the start menu.
2. Enter “
dcomcnfg” in the command line and press OK to open the dialog box
DCOM properties.
3. Select the register card
Standard properties.
4. Activate
DCOM on this computer.
5. Go to the
Standard authentification level and set “No”.
6. Go to the
Standard identification level and select “Identify”
7. Select the register card
Standard safety. Here you can set the standard authorization for
access and start.
8. Activate
Remote connection.
9. Click the button
OK to save the settings and close the dialog box.
Note!
With Windows 98/ME it is not possible to start OPC servers automatically through a DCOM connection;
a manual start is required.
Therefore we recommend to use Windows NT/2000/XP when connecting several PCs.