3 technical data, Technical data, 1 use of the machine for the intended purpose – Retsch AS 450 control Benutzerhandbuch

Seite 11: Notice, Caution, 2 emissions

Advertising
background image

Technical data

11

Pos : 5. 1 / 00005 Übersc hrift en/1. Übersc hrift en/1 Tec hnisc he Dat en @ 0 \ mod_1222344525522_9. doc @ 2407 @ 1 @ 1

3 Technical data

Pos : 5. 2 / 00005 Übersc hrift en/1. 1 Ü berschrif ten/ 1. 1 Ü bers chrift en BDA/ 11 Eins atz der M asc hine bei besti mmungsgemäß er Ver wendung @ 0\ mod_1226476732248_9. doc @ 3243 @ 2 @ 1

3.1 Use of the machine for the intended purpose

Pos : 5. 3 / 00010 Bedienungsanlei tungen Kapit elsamml ung en/AS450_c ontrol /0005 T ec hnische D at en/AS450 M odul Eins at z bei besti mmungsgemäße Ver wendung @ 0\ mod_1228723900289_9. doc @ 4295 @ @ 1

Target group: Owner/managing operator, operator

Machine type designation: AS450

The AS 450 is specially designed for test sieves with a diameter of 400 mm to 450
mm and offers a sieving surface that is 4 or 5 times as large as the sieving surface
in 200-mm-diameter sieves. Accordingly, the AS 450 reduces sieving times
considerably.

The AS 450 is suitable for the dry sieving of free-flowing and dispersed products
with a feed grain size up to a max. 125 mm.

A further advantage is the very high feed quantity of up to 25 kg, which depending
on the particle size and sieve mesh size can be separated in one operation. Work
is also made easier by the possibility of storing up to 9 parameter combinations
directly in the sieve shaker for frequently repeated sieving operations under the
same conditions.

For perfectly reproducible sieving results it is also possible to input sieve base
acceleration, which is independent of power frequency, instead of the amplitude
into the AS450.

All sieving parameters are digitally set, displayed and monitored. The amplitude is
monitored by means of a microprocessor-controlled measuring and control unit and
readjusted automatically if there are changes in load or voltage. Like all Retsch
control devices, the AS450 also has an integrated interface.

The device can be driven and set using EasySieve® evaluation software.
EasySieve® displays all sieving parameters on the screen before and during the
sieving operation.

Pos : 5. 4 / 00004 War nhi nweis eH 0007 HIN WEI S Ei ns atz ber eich des G erät es 8 St ündiger @ 1\ mod_1236240219096_9.doc @ 7693 @ @ 1

NOTICE

Area of use of the machine

This machine is a laboratory machine designed for 8-hour single-shift
operation.

This machine may not be used as a production machine nor is it
intended for continuous operation.

Pos : 5. 5 / 00004 War nhi nweis eV0022 VOR SICHT Veränder ung der Mas chi ne @ 0\ mod_1228918884599_9. doc @ 4858 @ @ 1

CAUTION

Changes to the machine

Changes to the machine may lead to personal injury.

Do not make any change to the machine and use spare parts and
accessories that have been approved by Retsch exclusively.

Pos : 5. 6 / 00005 Übersc hrift en/1. 1 Ü berschrif ten/ 1. 1 Ü bers chrift en BDA/ 11 Emmisionen @ 0\ mod_1226487095021_9. doc @ 3310 @ @ 1

3.2 Emissions

Pos : 5. 7 / 00004 War nhi nweis e/ V0043 VORSICHT Gehörs chäden (AS450) @ 3 \ mod_1282728704815_9. doc @ 22706 @ @ 1

Advertising