3 Mounting
The charge amplifier is supplied with two stainless mounting screws M4. The housing does not have
to be opened for mounting, because the screws are already inserted.
The dimensions of the mounting holes are 86 x 36mm (see Section 7.4), minimum thread depth 8mm.
The screws can be tightened through the holes in the lid using an hex wrench (3mm), and secured
with Loctite if necessary.
If longer screws are required, the lid must be unscrewed. Insert new screws with tooth lock washer.
For connecting the plug, see Section 5 Start up.
Notes:
For EMC reasons, we recommend to connect the mounting plate to earth (mounting position).
The charge amplifier can be fitted in any position, but if it is arranged vertically, mounting with plugs
pointing downward is preferred.
4 Function
4.1 Block diagram
uP
Gain
80%-Test
Offset
Charge
CH 1
Out
10
Ω
1
14
Offset
adjust
(sealed)
10
Ω
2
Peak
Out
Signal
GND
Case
=
=
11
24
12
13
5
6
7
25
8
20
21
19
L1
20kHz
Com
Logik
Input
80%
Test
Operate
Range
A0
Range
A1
Range
B0
Range
B1
Code
Supply +
Code 0
Code 1
Code 2
9,22
4
15
16
10
+5V
- 12V
+12V
3
Com
Logik
Output
Alarm 0
Alarm 1
Level 0
Level 1
L0
Range
var.
Reset
Block diagram
DACU 820
Supply
GND
Supply
+
Gain
80%-Test
Offset
CH2
Out
10
Ω
23
20kHz
DIP-1
polarity
change
18
17
TX
RX
RS232
TTL
+
-
+
-
DIP-2
polarity
change
DIP-3
GW-1
DIP-4
GW-2
DACU_820_BA_V2_1M.doc
24/40
Baumer Electric AG
Frauenfeld, Switzerland
4.2 Electrical connections
Electrical connections D-Sub 25
Pin
Function
Leads color DIN47100
1
Signal out CH1
white
2
Peak out
brown
3
Level 1 (In or Out)
green
4
Level 0 (In or Out)
yellow
5
Range B1 (CH2)
gray
6
Range B0 (CH2)
pink
7
Range A1 (CH1)
blue
8
Range A0 (CH1)
red
9
Supply GND
black
10
+ Supply
violet
11
Code 2
gray-pink
12
Code 0
red-blue
13
Code Supply +
white-green
14
Signal GND
brown-green
15
Alarm 1 (CH1)
white-yellow
16
Alarm 0 (CH1)
yellow-brown
17
RX
white-gray
18
TX
gray-brown
19
Com Logic Input
white-pink
20
Operate
pink-brown
21
80% Test
white-blue
22
Supply GND
brown-blue
23
Signal out CH2
white-red
24
Code 1
brown-red
25
Com Logic Output (Alarm)
white-black