Baumer BA DACU 820 Benutzerhandbuch
Seite 18

DACU_820_BA_V2_1M.doc
35/40
Baumer Electric AG
Frauenfeld, Switzerland
7 Technical data
7.1 Electrical data
Supply voltage range
10...40VDC
Current draw
< 1.5W
(1)
Measuring ranges CH1
±
100’000..500’000pC
Measuring ranges CH2
±
2’000..20’000pC
Output signal
±
10V
Accuracy
<
±
1%FS
Linearity
< 0.02%FS
Output offset
<
±
5mV
Noise
< 5mV
pp
(0.1Hz..100kHz)
(2)
Output resistance
10
Ω
Reset Operate Offset
<
±
10mV
Drift
< 0.03pC/s at 23°C
(3)
Offset voltage Q-input
<50
µ
V
Frequency response (-3dB)
0..20kHz
Control inputs
±
5V..
±
45V, galv. separated
Switching output
max. 45V
max. 100mA
galv. Separated
1) < 55mA at 24V
2) <20mVpp in the 2000pC range
3) Scope: charge input open and screened, DACU connected to operating voltage for min.
30min, RESET active, lid tightly closed.
7.2 Mechanical data
Control side connection
D-Sub 25-Pol, male
Sensor connection
BNC
7.3 Ambient conditions
Operating temperature
-5...+60°C
Storage temperature
-20...+80°C
Protection class
IP 40
EMC
EN 61000-6-2 Immunity
EN 61000-6-4 Emission
DACU_820_BA_V2_1M.doc
36/40
Baumer Electric AG
Frauenfeld, Switzerland
7.4 Dimensions
3
4
1
5
1
5
6
4
6
1
5
98
3
6
86
8 Accessories
Order code
5m connecting cable,
D-Sub 25 female,
open leads
(for leads colors see Section 4.2)
DZCS 05/DACU 8
Other accessories on request.