Baumer BA_DDBF Benutzerhandbuch

Seite 16

Advertising
background image

DDBF_BA_V2_0.doc

31/44

Baumer Electric AG

05.09.07/rut

Frauenfeld, Switzerland

4.7 Keypad

Enter

Esc

ON/OFF

Prog.

RESET

F1

F2

F3

ON/OFF

To switch the device on.
The device can only be switched off again 2
seconds after being switched on.
When the device is switched off, the display
is switched off first, and the device is
switched off 2 seconds later.

RESET

To reset (set the display to zero).

Prog.

o

To change to programming mode

o

To store and leave the current setting mode

Cursor keys

Enter

To execute the selected function

ESC

o

To terminate a function in Prog. Mode

o

To quit without saving

F1…F3

not assigned

4.8 LED’s


The Displaybox has two status LED.

Caution:
When the red LED light is on the measuring
values are not valid!

4.8.1

Error LED

ON

blinking

OFF

Error
(rot)

Hardware error

Configuration error (CalcPara) Fully functional

Causes

•

Not within Reset range

•

Failed Sensor connection

•

No Sensor connected on
active channel
(only DDBF-4Sx)

•

The set Calculation
parameters are not within
the tolerable range

4.8.2

RESET disable LED

ON

OFF

Reset disable
(yellow)

•

RESET function is disabled

•

RESET function only for PEAK value

•

RESET function enabled


DDBF_BA_V2_0.doc

32/44

Baumer Electric AG

05.09.07/rut

Frauenfeld, Switzerland

4.9 Display background lighting

Battery mode:
Background lighting expires after 20 seconds after the last key was pressed.

Power supply mode:
Display backlight is constantly active.

4.10 LCD display

4.10.1 Start up procedure

After the device is started with the ON key, the display shows the following:

-

“All segments”

-

Baumer / sensopress

-

“All segments”

-

“DDBF 2-Sx” or “DDBF 4-Sx”

-

“All segments”

-

Software and hardware version

4.10.2 Display DDBF 2-SC

Note:
If the value exceed the maximum of “9999”, “OVFL” is shown on the Display.
For a valid indication in kN or t the calculation parameters must be set correctly.

[DISPLAY CH A]

[DISPLAY CH B]

[DISPLAY CH A + B]

[DISPLAY AVG ]

[DISPLAY SUM]

DMS1 324 uE

PEAK 342 uE

DMS2 350 uE

CH A 337 uE

1: 324 2: 350

CH A 337 uE

1: 250 2: 272

CH B 261 uE

AVG 299 uE

PEAK 305 uE

CH A 337 uE

CH B 261 uE

Comment:
CH A: Mean value of DMS1 and
DMS2
PEAK: Shows the peak value of
the selected channel (e.g. CH A).
S/G1 (DMS1) or S/G2 (DMS2):
The strain values of the individual
strain gauges of the selected
channel (e.g. CH A)

Comment:
1 or 2: The strain values of the
individual strain gauges of the
above channel in

µε

(

µ

m/m)

Comment:
AVG: Average of CH A and CH B
PEAK: Displays the peak value
of AVG.