PEAK 127 kN

CH A 125 kN

DMS1 324 uE

DMS2 350 uE

1: 324 2: 350

CH A 337 kN

1: 250 2: 272

CH B 261 kN

SUM 598 kN

PEAK 601 kN

CH A 337 kN

CH B 261 kN

Comment:
S/G1 (DMS1) or S/G2 (DMS2):
The strain values of the individual
strain gauges of the selected
channel in

µε

(e.g. CH A)

Comment:
1 or 2: The strain values of the
individual strain gauges of the
above channel in

µε

(

µ

m/m).

Comment:
SUM: If the unit kN or t is chosen,
the sum of both channels is
displayed.
PEAK: Displays the peak value
of SUM.

4.10.3 Display DDBF 4-Sx

Note:
If the value exceed the maximum of “9999”, “OVFL” is shown on the Display.
For a valid indication in kN or t the calculation parameters must be set correctly.

Default Display in [

µε

]

Display at selected Unit [kN] or [t]

AVG 223 uE

PEAK 451 uE

A 220 B 226

C 220 D 226

SUM 2300 kN

PEAK 3450 kN

A 570 B 580

C 574 D 576

Comment:
AVG: Average of the active channels
PEAK
: Displays the positive peak value of AVG.
CH A to D: Strain value of the corresponding
channel in

µε

(

µ

m/m).

If a channel is not activated „----“ is shown.

Comment:
SUM: Sum of all active channels.
PEAK
: Displays the positive peak value of SUM.
CH A to D: measuring value of corresponding
channel in kN or t.
If a channel is not activated „----“ is shown.

DDBF_BA_V2_0.doc

34/44

Baumer Electric AG

05.09.07/rut

Frauenfeld, Switzerland

5 Programming

5.1 Selecting Parameter

PROG

ESC

PARA 1
DISPLAY CH1

PARA 3
RESET ENABLE

CH1 235 uE

1: 233 2: 237

PARA 5

CALC PARA

PARA 6

OUTPUT 1

PARA 7

OUTPUT 2

PARA 4

UNIT uE

PARA 2

CHANGE-POL OFF

PARA 8

Channel Select

Set up display
(in the case of the DDBF 4-Sx this indication
does not appear)


Activate change of polarity



Deactivate function of Reset button




Set up display unit



Set calculation parameters



Select analog outputs
(only in case of DDBF 4-Sx)


Select analog outputs
(only in case of DDBF 4-Sx)



Select channels
(only in case of DDBF 4-Sx)

Note:
After the “Prog.” Button is pressed, in the case of the
DDBF 2-SC “PARA1” (set up display) appears, and
in the case of the DDBF 4-Sx “PARA2” (change
polarity) appears.

“Prog”

With this, the user goes from measured value display to parameter selection.

“Esc”

With this, the user returns to measured value display without saving the settings.