5.6 Calculation parameters
ENTER
ESC
CALC PARA
E-MOD = 200
CALC PARA
D = 100 mm
PARA 5
CALC PARA
CALC PARA
d = 20 mm
“Enter”
To switch from PARA5 into
parameter setting
“Esc”
Back to PARA5 without saving
the setting
To select the calculation
parameter
Comment:
D = shaft diameter
d = hole diameter
Formula:
F = A x E x
ε
F = force [N]
A = cross section [mm
2
]
E = Young’s modulus [N/ mm
2
]
ε
= strain [m/m] (
µε
=
µ
m/m)
5.6.1
Setting Young’s modulus
CALC PARA
E-MOD = 000
ENTER
CALC PARA
E-MOD = 200
ESC
PROG
CALC PARA
E-MOD = 100
CALC PARA
E-MOD = 900
CALC PARA
E-MOD = 000
CALC PARA
E-MOD = 010
CALC PARA
E-MOD = 090
CALC PARA
E-MOD = 200
CALC PARA
E-MOD = 000
CALC PARA
E-MOD = 009
CALC PARA
E-MOD = 001
.................
.................
.................
Note:
Setting range 0 … 499 kN / mm
2
DDBF_BA_V2_0.doc
38/44
Baumer Electric AG
05.09.07/rut
Frauenfeld, Switzerland
“Enter”
To switch from CALC PARA/E-MOD to the setting area
“Esc”
Back to CALC PARA/E-MOD without saving the setting
“Prog.”
Back to CALC PARA/E-MOD saving the setting
To increment the flashing digit
To decrement the flashing digit
To select the digits to be adjusted (the digits then flash)
5.6.2
Setting shaft diameter D
ENTER
ESC
PROG
CALC PARA
D = 000 mm
CALC PARA
D = 001 mm
CALC PARA
D = 009 mm
CALC PARA
D = 000 mm
CALC PARA
D = 010 mm
CALC PARA
D = 090 mm
CALC PARA
D = 100 mm
CALC PARA
D = 000 mm
CALC PARA
D = 100 mm
CALC PARA
D = 900 mm
.................
.................
.................
Note:
Setting range 10 … 599 mm
“Enter”
To switch from CALC PARA/D to the setting area
“Esc”
Back to CALC PARA/D without saving the setting
“Prog.”
Back to CALC PARA/D saving the setting
To increment the flashing digit
To decrement the flashing digit
To select the digits to be adjusted (the digits then flash)