Configuration user interface – Meinberg GPS LANTIME Benutzerhandbuch

Seite 13

Advertising
background image

Configuration User Interface

There are several ways to configure the LANTIME parameters:


Command Line Interface (CLI) via TELNET
Command Line Interface via SSH
Command Line Interface via serial interface terminal (BGT versions only)
HTTP Interface
Secure HTTP Interface (HTTPS)
SNMP Management

To put LANTIME into operation for the first time an IP address is to enter via the front
panels keys and LC display (refer to: DHCP IPv4 or AUTOCONF IPv6). LANTIME
variants without LC display have to be given the IP address via the serial interface in
the front panel, running a terminal software e.g. on a laptop. If once the IPv4 address,
netmask and IPv4 GATEWAY is configured, or the network interface is initialised by
IPv6 SCOPE-LINK, the LANTIME is accessible from any computer in the network
(remote).

To set up a TELNET connection the following commands are to enter:


telnet 198.168.10.10

// LANTIME IP address

user: root
password: timeserver

With “setup” the configuration program is to start.

To set up a SSH connection the following commands are to enter:


ssh [email protected] //
LANTIME IP address
password: timeserver

With “setup” the configuration program is to start.

To set up a HTTP connection the following address is to enter in a web browser:


http://198.168.10.10

// LANTIME IP address

password: timeserver

To set up a Secure HTTP (HTTPS) connection the following address is to enter in a
web browser:


https://198.168.10.10

// LANTIME IP address

password: timeserver

13

Advertising