Power Jacks Rolaram Actuators Benutzerhandbuch
Seite 12
ROLARAM ™ Actuator
Elektrohubzylinder
12
Technical Data
Type:
Four-wire PNP/NPN/NO/NC
programmable
XS1-M18KP340
Brass housing
Nominal sensing distance S
n
5mm
Weight (kg)
0,120
Connecting Cable
Leitung 4 x 0,34 mm
2
, 2m lang (1)
Degree of protection
IP 68
Sensing distance S
sr
0…4mm
Repeat accuracy R
3% von S
r
Differential Travel H
1…15% von S
r
Operating temperature
-
25 …+80°C
Output state indicator
LED rundum
Voltage U
o
12…24 V
Operating voltage U
b
(including residual ripple)
10…38 V
Switching power I
0…200 mA, including overload and short circuit connection
Voltage drop U
d
(output controlled)
2,6 V
Residual current l
r
(output locked)
-
Idle current l
a
10 mA
Maximum switching frequency f
2000 Hz
Delay times
Stand-by delay t
v
:
5 ms; switch-on time t
on
:
0,15 ms; switch-off time t
off
:
0,35 ms
Connecting Options:
(1) Proximity switches with different cable lengths available:
Connection cable:
Additional type designation with:
Additional weight
5m
L1
0, 120 kg
10m
L2
0, 320 kg
(2) Connectors:
(3) Direct connection ~ 24 V bridge rectifier possible without smoothing
(4) ~ 24 V bridge rectifier with smoothing.