Power Jacks Rolaram Actuators Benutzerhandbuch

Seite 12

Advertising
background image

ROLARAM ™ Actuator
Elektrohubzylinder

12





































































































Technical Data
Type:
Four-wire PNP/NPN/NO/NC
programmable

XS1-M18KP340

Brass housing


Nominal sensing distance S

n

5mm

Weight (kg)

0,120

Connecting Cable

Leitung 4 x 0,34 mm

2

, 2m lang (1)

Degree of protection

IP 68

Sensing distance S

sr

0…4mm

Repeat accuracy R

3% von S

r

Differential Travel H

1…15% von S

r

Operating temperature

-

25 …+80°C

Output state indicator

LED rundum

Voltage U

o

12…24 V

Operating voltage U

b

(including residual ripple)

10…38 V

Switching power I

0…200 mA, including overload and short circuit connection

Voltage drop U

d

(output controlled)

2,6 V

Residual current l

r

(output locked)

-

Idle current l

a

10 mA

Maximum switching frequency f

2000 Hz

Delay times

Stand-by delay t

v

:

5 ms; switch-on time t

on

:

0,15 ms; switch-off time t

off

:

0,35 ms


Connecting Options:
(1) Proximity switches with different cable lengths available:
Connection cable:

Additional type designation with:

Additional weight

5m

L1

0, 120 kg

10m

L2

0, 320 kg

(2) Connectors:
(3) Direct connection ~ 24 V bridge rectifier possible without smoothing
(4) ~ 24 V bridge rectifier with smoothing.