Sequenzzeiten - Hauptzeiten (Ein/Aus/Delay/Warten)

Times are set to the step in A (Active) or B (Next) depending on the setting for times (SETUP &
TIME).

Function

Key

Feedback

In time

[#] [IN]

A time is set for the
incoming channels.

Out time

[#] [OUT]

A time is set for the
outgoing channels.

In- and Out time

[#] [TIME]

A time is set for the in- and
outgoing channels.

Delay In time

[#] [DELAY] & [IN] A delay time is set for the

incoming channels.

Delay Out time

[#] [DELAY] &
[OUT]

A delay time is set for the
outgoing channels.

Wait, Followon or
Alert time *

Sequences - Sequence
List

Enter the time in the WFA
Time
column of the
Sequence List. You can
toggle between Wait, Alert
or Followon in the previous
column

* A Wait or Followon time will automatically execute a crossfade to the Step it is assigned to. The
difference is that a Wait time starts counting down after the END of the previous crossfade, while the
Followon time starts counting down from the START of the previous crossfade. Wait times is the
default setting. The Alert time will count down as a warning to the operator, but not execute the next
fade. See

Sequence Times - Alert Times

.

See

Times Soft Key Page

.

You can view/edit the main times in the

Sequence List

.