2.2.2. Serial interface COM1, COM2 X1, X2


The serial interface COM1 corresponds with the programming interface (PG) on the Shuttlebox. By
means of the serial interface COM2, it is also possible to access the PLC (e. g. interface for
visualisation). For this purpose, a 9-pole SUB-D connector can be attached via a flat ribbon cable. The
pin allocation is as given below:

PIN SUB-D PIN connection

strip X1, X2

PIN SUB-D

PIN connection
strip X1, 2

1 1

8 6

6 2

4 7

2 3

9 8

7 4

5 9

3 5

10


2.2.3. Ethernet interface X11 (option)


The Ethernet interface is optional. The pin allocation is given below.






PIN Function PIN Function

1 TX+ 2 TX-
3 RX+ 4 RX-
5 GND 6 GND
7

LINK LED

8

ACTIVE LED

9 NC 10 +5V


2.2.4. Fieldbus diagnosis interface X14


The Fieldbus diagnosis interface corresponds with the DIAG interface on the Shuttlebox. By means of
this interface, it is possible to configure the Fieldbus module. For this purpose, a 9-pole SUB-D
connector can be attached via a flat ribbon cable. The pin allocation is as given below:

PIN SUB-D PIN connection

strip X14

PIN SUB-D

PIN connection
strip X14

1 1

8 6

6 2

4 7

2 3

9 8

7 4

5 9

3 5

10

PCI bus