2.2.8. Connection to Shuttlebox X10


This interface is for connecting the PCMatic

®

-Shuttlebox. The 25-pole SUB-D connector is connected

in an identical way. As standard equipment, a 2 m connecting cable is included in the initial delivery.
Other lengths can be supplied on request. Alternatively, an adapter cable is available, to provide a
connection between the programming device and the Fieldbus. The pin allocation of the connector is
detailed below:

PIN Function PIN Function

1

+24 V

14

TXD PG

2

+24 V

15

RXD PG

3

+24 V

16

CTS PG

4

TXD Fieldbus diagnosis

17

RTS PG

5

RXD Fieldbus diagnosis

18

Alarm 2

6 GND 19

Alarm

1

7 GND 20

Start/Stop

switch

8 GND 21

Reset

PCM

9

LED ST1 (yellow)

22

Activate PCM UPS

10

LED RDY (yellow)

23

LED RUN PLC (green)

11

LED RUN (green)

24

CTS Fieldbus diagnosis

12

LED Status (yellow)

25

Power fail UPS

13

LED Error (red)


All LEDs are attached to a 5 V supply without a preliminary resistor. By use of the Fieldbus diagnosis, it
is also possible to transfer the Fieldbus configuration via PCMCon. The programming device interface
corresponds with the serial interface COM1. For the Start/Stop switch, 5 V corresponds with the Stop
status. For Reset PCM, 5 V corresponds with the Reset value. The UPS signals are used by the
PCMatic

®

-Shuttlebox.

2.2.9. Fieldbus interface X15


See Chapter on Technical Information