Specifications – WIKA DIH62 Benutzerhandbuch
Seite 10

10
WIKA operating instructions models DIH50, DIH52, DIH62
GB
14008548.02 03/2012 GB/D
3. Specifications
Specifications
Models DIH50
Models DIH52, DIH62
Display
■
Principle
LCD, rotatable in 10° steps
■
Measured value
7-segment LCD, 5-digit, character size 9 mm
■
Bar graph
20-segment LCD
■
Information line
14-segment LCD, 6-digit, character size 5.5 mm
■
Status indicators
: HART
®
mode (signalling of HART
®
parameter adoption)
: Unit lock
: Warnings or error messages
■
Indication range
-9999 ... 99999
Measuring rate
4/s
Accuracy
±0.1 % of the measuring span
±0.05 % of the measuring span
Temperature coefficient
±0.1 % of the measuring span/10 K
Permitted current carrying
capacity
100 mA
Voltage drop
< DC 3 V (< DC 2 V at 20 mA); supply via current loop
HART
®
functionality
■
Access control
-
Secondary master
■
Automatically set
parameters
Unit, measuring range
■
Available commands -
Unit, measuring range start/end, format, zero
point, span, damping, polling address
■
Identified commands Generic mode:
1, 15, 35, 44
Generic mode:
0, 1, 6, 15, 34, 35, 36, 37, 44
■
Multidrop
not supported
Measured values are automatically taken
from the HART
®
digital data and displayed
Permissible
■
Ambient temperature -20 ... +85 °C
-20 ... +70 °C
■
Vibration resistance
3 g per EN 60068-2-6
■
Shock resistance
30 g per EN 60068-2-27
CE conformity
■
EMC directive
2004/108/EC, EN 61326 emission (group 1, class B) and interference im-
munity (industrial application)
Field case
Model DIH50, DIH52
Model DIH62
Material
Aluminium, window in
polycarbonate
Aluminium, plastic, stainless steel; window
from polycarbonate
Colour
Night blue, RAL 5022
Night blue, RAL 5022 (aluminium, plastic)/
silver (stainless steel)
Cable glands
3 x M20 x 1.5 or 3 x ½ NPT
Ingress protection
IP 66
Weight
approx. 1.5 kg
Dimensions
see drawing