Maintenance and cleaning / 8. faults, Gb 7. maintenance and cleaning, Faults – WIKA TR10-B Benutzerhandbuch

Seite 15

Advertising
background image

WIKA operating instructions resistance thermometers per EN 14597

3132465.01 07/2011 GB/D

15

GB

7. Maintenance and cleaning

7.1 Maintenance

This resistance thermometer is maintenance-free.

Repairs must only be carried out by the manufacturer.

7.2 Cleaning

CAUTION!

Clean the instrument with a moist cloth.

Electrical connections must not come into contact with moisture.

Wash or clean the dismounted instrument before returning it, in order to

protect personnel and the environment from exposure to residual media.

Residual media in dismounted instruments can result in a risk to persons, the

environment and equipment. Take sufficient precautionary measures.

For information on returning the instrument see chapter "9.2 Return".

8. Faults

Faults

Causes

Measures

No signal/ line breakage Mechanical load too high or

overtemperature

Replace probe or measuring insert with

a suitable design

Erroneous measured

values

Sensor drift caused by

overtemperature

Replace probe or measuring insert with

a suitable design

Sensor drift caused by chemical

attack

Use a design with thermowell

Erroneous measured

values (too low)

Entry of moisture into cable or

measuring insert

Replace probe or measuring insert with

a suitable design

Erroneous measured

values and response

times too long

Wrong mounting geometry, for

example mounting depth too deep or

heat dissipation too high

The temperature-sensitive area of the

sensor must be inside the medium,

and surfaces must be isolated

Deposits on the sensor or thermowell Remove deposits

Measurement signal

"comes and goes"

Cable break in connecting cable or

loose contact caused by mechanical

overload

Replace probe or measuring insert

with a suitable design, for example

equipped with a strain relief or a

thicker conductor cross-section

Corrosion

Composition of the medium not

as expected or modified or wrong

thermowell material selected

Analyse medium and then select a

more-suitable material or replace

thermowell regularly

Signal interference

Stray currents caused by electric

fields or earth loops

Use shielded connecting cables, and

increase the separation from motors

and power cables.

Earth circuits

Eliminate potential differences by

using galvanically isolated transmitter

power supplies or transmitters.

7. Maintenance and cleaning / 8. Faults

Advertising