1 Functional description


The DABU MP4M is a bridge amplifier for strain gage bridges containing following features:

•

Analog output signal

•

Analog output for PEAK-value

•

Tare function (Reset)

•

Free configurable strain gage bridges (2 x ¼ bridge, half bridge, full bridge)

•

LCD Display with background light

•

Adjustable limits with switching outputs

•

For DIN rail mounting

2 Safety and operating notes

2.1 Use as specified

•

The bridge amplifier must be operated exclusively at the specified purposes.

2.2 Putting into operation

•

The bridge amplifier must be mounted only by a qualified electrician.

•

Wiring on the plug or in the control cabinet must be carried out only in the off-power state.

•

Follow the machine manufacturer’s instructions.

2.3 Safety notes

•

Before the system is put into operation, check all electrical connections.

•

If the mounting, electrical connection or other work on the bridge amplifier is not carried out
correctly, wrong functioning or failure of the charge amplifier may result.

•

Danger to personnel and damage to the system and operating equipment because of failure or
wrong functioning of the bridge amplifier must be excluded by suitable safety actions.

•

The bridge amplifier must not be operated outside the limits which are given in the Technical Data
(see Section

5 Technical Data).

Failure to observe the safety notes can result in wrong functioning and material and
personal damage!

2.4 Transport and storage

•

Transport and storage only in original packing

•

Do not let the bridge amplifier fall or allow it to be shaken vigorously

2.5 Organisational actions

•

Ensure that the personnel have read and understood the operating instructions, particularly the
section “Safety and operating notes”.

•

In addition to the operating instructions, generally applicable legal and other binding regulations
for accident prevention and environmental protection must be reliably observed.

DABx_MP4M_BA_V2_3m.doc

18/28

Baumer Electric AG

19.12.07/rut

Frauenfeld, Switzerland

3 Mounting

The bridge amplifier can be fitted on the DIN-rail very easily. Plugs connection see chapter 4.3,
‘Electrical connections’.

Notes:
For EMC reasons, we recommend to earth the sensor cable via the delivered clamping bow. The
earth connection on control side has to be connected on earth as well.

4 Function

4.1 Overview of the operating controls

4.2 Block diagram

S+ 6

S- 7

D-Pot

+5V

DAC
12bit

DAC
12bit

LED1
green

LED2
green

LCD

Error LED
red/green

+Vs

+5V

3

uP

A

D

12bit

E-’ 9

E-’ 10

E- 11,12

E+’ 3

E+ 1,2

Shield 13

Shield
Shield

1 +Vs

3,5,9 GND

2 Vout/Iout (Signal)

4 Vout 2/Iout 2 (Peak)

13 Error

7 Switch 2

6 Switch 1

8 Reset

11 Mode_0

12 Mode_1

10 Com_Logic

Connecting clip
Sensor side

Rotary button

Connection clip
Control side

External
DIP-Switch

Internal
DIP-Switch

Left side

LCD–Display