1 Functional description


The DABU MP4M is a bridge amplifier for strain gage bridges containing following features:

Analog output signal

Analog output for PEAK-value

Tare function (Reset)

Free configurable strain gage bridges (2 x ¼ bridge, half bridge, full bridge)

LCD Display with background light

Adjustable limits with switching outputs

For DIN rail mounting

2 Safety and operating notes

2.1 Use as specified

The bridge amplifier must be operated exclusively at the specified purposes.

2.2 Putting into operation

The bridge amplifier must be mounted only by a qualified electrician.

Wiring on the plug or in the control cabinet must be carried out only in the off-power state.

Follow the machine manufacturer’s instructions.

2.3 Safety notes

Before the system is put into operation, check all electrical connections.

If the mounting, electrical connection or other work on the bridge amplifier is not carried out
correctly, wrong functioning or failure of the charge amplifier may result.

Danger to personnel and damage to the system and operating equipment because of failure or
wrong functioning of the bridge amplifier must be excluded by suitable safety actions.

The bridge amplifier must not be operated outside the limits which are given in the Technical Data
(see Section

5 Technical Data).

Failure to observe the safety notes can result in wrong functioning and material and
personal damage!

2.4 Transport and storage

Transport and storage only in original packing

Do not let the bridge amplifier fall or allow it to be shaken vigorously

2.5 Organisational actions

Ensure that the personnel have read and understood the operating instructions, particularly the
section “Safety and operating notes”.

In addition to the operating instructions, generally applicable legal and other binding regulations
for accident prevention and environmental protection must be reliably observed.

DABx_MP4M_BA_V2_3m.doc

18/28

Baumer Electric AG

19.12.07/rut

Frauenfeld, Switzerland

3 Mounting

The bridge amplifier can be fitted on the DIN-rail very easily. Plugs connection see chapter 4.3,
‘Electrical connections’.

Notes:
For EMC reasons, we recommend to earth the sensor cable via the delivered clamping bow. The
earth connection on control side has to be connected on earth as well.

4 Function

4.1 Overview of the operating controls

4.2 Block diagram

S+ 6

S- 7

D-Pot

+5V

DAC
12bit

DAC
12bit

LED1
green

LED2
green

LCD

Error LED
red/green

+Vs

+5V

3

uP

A

D

12bit

E-’ 9

E-’ 10

E- 11,12

E+’ 3

E+ 1,2

Shield 13

Shield
Shield

1 +Vs

3,5,9 GND

2 Vout/Iout (Signal)

4 Vout 2/Iout 2 (Peak)

13 Error

7 Switch 2

6 Switch 1

8 Reset

11 Mode_0

12 Mode_1

10 Com_Logic

Connecting clip
Sensor side

Rotary button

Connection clip
Control side

External
DIP-Switch

Internal
DIP-Switch

Left side