Baumer NE218 Benutzerhandbuch
Seite 32

NE218
32
www.baumer.com
Change
Start count SC
➜
Press the
key.
The current start count SC is displayed for reading.
The LED „SC“ shines.
➜
Enter start count via
and
keys.
Press the
key.
Totalizer ∑
➜
Press the
key.
The current total is displayed for reading.
The LED „∑“ shines.
If the value 999999 is exceeded, its display will be shown in two
steps. 1st step: Display of the first 6 digits. 2
nd
step: marked by an
“H“, display of 7
th
and 8
th
digit.
Display of each value for approx. 3 seconds.
Reset
➜
Press the
key.
Reset
Time meter
➜
Press the
key.
The operating time is displayed for reading.
The LED „ “ shines.
➜
Press the
key.
Change
Scaling factor SF
The scaling factor allows the display of fractions or multiples of the
counting pulses.
Setting range: 0.0001 to 9999.99. Setting ex factory: 1.0000.
Press the
key.
The current scaling factor „SF“ is displayed for reading.
➜
Enter scaling factor „SF“ via
and
keys.
Press the
key.
Example In the case of a length measurement by means of encoder and
cyclometer, the circumference of the cyclometer measures 200
mm and the encoder supplies 500 pulses per revolution. The mea-
surement is to be displayed in mm. The scaling factor is calculated
as follows:
Scaling factor =
Circumference
=
200
= 0.4000
Pulses
500
Press the
key again, the current count XP is re-displayed.