Baumer NE218 Benutzerhandbuch
Seite 36

NE218
36
www.baumer.com
Programming field 3
Here all machine-related functions and values, as well as the inter-
face parameters are programmed.
The factory setting is marked in each case with a *.
Line 22
Operating modes
0 * Step preset
1 Main presets
2 Parallel comparison
3 P1 Self-adjusting preset
Line 24
Decimal point (for XP, P1, P2, SC,
Σ
)
0 * No decimal point
1 00000.0
2 0000.00
3 000.000
4 00.0000
Line 25
Counting mode
0 * Track A and UP/DOWN signal on track B
1 Differential counting, track A adding, track B subtracting (A-B)
2 Totalizing, tracks A and B adding (A+B)
3 Track A 90° track B single evaluation
4 Track A 90° track B twofold evaluation
5 Track A 90° track B fourfold evaluation
To set track A at 90° to track B, the input frequencies for both tracks
must be adjusted to 10 kHz (lines 26 and 27).
Line 26
Frequency main counter track A
0 * 10 kHz
1 25 Hz
2 3 Hz
Line 27
Frequency main counter track B
0 * 10 kHz
1 25 Hz
2 3 Hz
Line 28
Input logic and operating threshold of signal inputs
0 * PNP Switching threshold 10 V
1 NPN Switching threshold 10 V
2 PNP Switching threshold 5 V
3 NPN Switching threshold 5 V,
or for Namur without ex protection
4 PNP Switching threshold 2.5 V
5 NPN Switching threshold 2.5 V