NE218
38
www.baumer.com
Line 41
Function of batch counter
0 * Totalizer (counting process parallel to main counter)
1 Batch counter (automated counting process when reching P2)
Line 42
Multiplication Batch counter (only if line 41 = 1)
1 * Default
max. 999
Line 43
Actual value Correction (only if line 31 = 4)
0 * No correction value
max. 999999
Line 44
Display after power failure
0 * No indication of power failure
1 Indication of power failure (7-segment display blinks)
Line 51
Baud rate
0 * 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 52
Parity
0 * Even parity
(7 data bits)
1 Odd parity
(7 data bits)
2 No parity
(8 data bits)
Line 53
Stop bits
0 * 1 Stop bit
1 2 Stop bits
Line 54
Address
0 * from
99 to
Line 55
Assignment Output value via interface (line 31 = 5)
0 * Display value
1 XP
2 P1
3 P2
4 SC
5
Σ
6
7 SF
Line 56
RS422: Control contacts TxD+ and/or TxD
0 * Switched in sense of transmission when transmitting, in
sense of reception when receiving
1 Always in sense of transmission
The dash line indicates the end of the third programming field.
To leave the programming mode enter the key
.
Counter now reverts to the operating mode.