Line 29
Reset main counter (control input 1, terminal 11)
0 * Automatic reset and external, statically effective
1 Automatic reset and external, edge active
2
External static
3 External edge-triggered
4 External with “Start function“
Line 31
Function control input 2 (terminal 12)
0 * Stop
1 Hold
2 Keylock
3 Operating time meter counts/stops, counts as long as signal
present
4 Correction of actual value
5 Print (only for interface operation)
Line 33
Output logic
0 * Both outputs as normally open
1 P1 normally closed, P2 normally open
2 P1 normally open, P2 normally closed
3 Both outputs as normally closed
Line 35
Output time P1
0.01 Minimum signal duration
* 0.25 Default
99.99 Maximum signal duration
LAtCH = Latched signal (by pressing the
- key)
Line 36
Output time P2
0.01 Minimum signal duration
* 0.25 Default
99.99 Maximum signal duration
LAtCH = Latched signal (by pressing the
- key)
Line 37
Take-over preset P1, P2, SC
0 * Effective immediately
1 At reset
Line 38
Setting range P1, P2 and SC
0 * Only in positive counting range
1 In positive and negative counting range
Line 39
Assignment of function key F
0 * Without function
1 XP
2 P1
3 P2
4 SC
5
Σ
6
7 SF
Line 40
Code settings
0 * No code
max. 9999