6technical data – TechniSat TechniRouter 5/1x8 K Benutzerhandbuch

Seite 41

Advertising
background image

41

EN

6

Technical Data

1)

Values at the lower ... upper band limits

2)

All other trunk and subscriber lines with signal

3)

Conforming to EN 60728-3: namely IMA3 at the output: 35 dB

TechniRouter

5 / 1x8 G

5 / 1x8 K

5 / 2x4 G

5 / 2x4 K

Article number

0000/ 3290

0000/ 3291

0000/3292

0000/3293

Return path, terrestrial: 5..790 MHz
Satellite: 0.95 ... 2.15 GHz

RW /

Terr.

Sat.

RW /

Terr.

Sat.

RW /

Terr.

Sat.

RW /

Terr.

Sat.

Number of trunk inputs

1

4

1

4

1

4

1

4

Number of trunk outputs

1

4 1

4

Number of subscriber cables

1 1 2 2

Subscriber per cable

maximum 8

maximum 8

maximum 4

maximum 4

Subscriber number and
receiving channels

(User bands)

channel 1 : 1284 MHz
channel 2 : 1400 MHz
channel 3 : 1516 MHz
channel 4 : 1632 MHz
channel 5 : 1748 MHz
channel 6 : 1864 MHz
channel 7 : 1980 MHz
channel 8 : 2096 MHz

channel 1 : 1284 MHz
channel 2 : 1400 MHz
channel 3 : 1516 MHz
channel 4 : 1632 MHz

Trunk loss

2...3

1)

dB

3 ... 5

dB

2...3

dB

3...5

dB

Gain of the subscriber signals

-1 dB

13...18

dB

-8 dB

13...18

dB

-5 dB

17...22

dB

-12 dB

17...22

dB

Reflection loss

10 dB

Isolation Trunks
Subscriber

45 dB 2)

30 dB

Input level, satellite signal
recommended

70 dBµV

minimum (

sensitivity)

40 ... 35 dBµV, although the subscriber cables, depending on

length, must be supplied with far higher levels.

maximum

80 dBµV

3)

Phase noise

-60 dBc/Hz (SSB @ Δf = 1 kHz from the carrier)

Power supply

TechniRouter & LNB are supplied from the receivers, optional for LNB:

wall power supply 230 V / 13V, 460 mA DC,short and overload protected

Power requirement in operation

Maximum 5 W / 410 mA from the receiver

receiver off

0 W without power supply / 3 W with power supply

with LNB

(200 mA)

p.a.

Depending on TV habits, Benchmark 10 kWh (without power supply)

Control by the receiver

DiSEqC-Protocol as per to EN 50494

Unicable, OLT, SCR or SCD

Special features

Traffic indicator = installations aid, no power supply necessary

Screening attenuation

In accordance with EN 50083-2 (TechniSelect S)

Environmental conditions

-25...+55°C, Surge protection at inputs and outputs: < 5 kV, IP 50

Intermediate amplifier 5Z(2)/NT, (double) tap 5/2A, passive distributor 5P

Accessories
deployable in the trunk
deployable in the
subscriber line

attenuator, splitter,

loop through sockets with 10 dB or 13 dB tap loss, terminal socket

Dimensions l x w x h(mm),weight G

: 150 x 114 x 43 , 0,4 kg K : 150 x 123 x 43 , 0,4 kg