Activate the standalone mode:
The standalone mode is activated in the menu STANDALONE, RUN.
To enter the functions press “ENTER” (keep it down) and press “ESC” in addtion.
The A12 will execute sequence in a repeating loop.
To leave press “ESC” and hold it down and press “ENTER” in addition.

Operation in Master-Slave mode:
To set a fixture to slave-mode navigate to REMOTE.
To activate the slave funciton press “ENTER” (keep it down) and press “ESC” in addtion.
The display will show either REMOTE INACTIVE if no DMX-signal is being
received or REMOTE ACTIVE if a DMX-signal is being received.
To leave this fuction press “ESC” (keep it down) and press “ENTER” in addition.
Connect the A12 with DMX cables.
Select STANDALONE/RUN with the master fixture. Start function by pressing “ENTER”
(keep it down) and pressing “ESC” in addition.
All connected fixtures will repeat the steps synchronized to the master fixture.
To leave the menu press “ESC” (keep it down) and press “ENTER” in addition.
If you realize that a fixture reacts inaccurate check if the display shows REMOTE ACTIVE.

one step of the sequence can be deleted. Chose the step and confirm the

With DELETE
function

with ENTER.

To

reset the DMX values of a step use RESET STEP. Select the step and confirm with

“ENTER”.

All DMX values of the step will be set on zero.

With

CLEAR ALL the complete sequence will be deleted and the display will show

STEP 01/01.

Store cues from a DMX controller:
The

DMX values can also be programmed by means of a DMX console.

. Programm the DMX-values

with an external DMX-console. To capture the data press „ENTER“. The fixtures display

. To insert, delete or reset use the keys of the control panel

of the fixture.

Enter the STANDALONE menu and navigate to CAPT DMX

will show START CAPTURE