Sharp AL-1651CS Benutzerhandbuch

Seite 76

Advertising
background image

AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 6

7

06

Interval aging (INTERVAL
AGING)

[Function]
Copying is repeated to make the set quantity of copies.
When the test command is executed, warm-up is performed and the ready lamp is lighted.
Enter the copy quantity with the [10KEY] and press [ENTER/START] key, and copying is executed to
make the set quantity of copies, and the ready state is kept for 3sec, and copying is executed again to
make the set quantity of copies. These operations are repeated.
To cancel the test command, turn off the power or execute a test command which executes hardware
reset.

[Operation]

08

Shift to copy with warm-up
display (Shift to equivalent to
CA key) (W-UP C-MODE)

[Function]
Enter the test command code, and warm-up is started and warm-up time is counted for every second
from 0 and displayed.
When [CA] key is pressed during counting up, "0" is displayed on the display and counting is stopped.
However, warm-up is continued.
After completion of warm-up, counting is terminated. (The aging function is removed from test com-
mand 7-01.)

[Operation]

8

01

Developing bias output
(DVLP BIAS SET.)

[Function]
When [ENTER/START] key is pressed, the developing bias signal is turned ON for 30sec.

When, however, an actual output value is measured, use test command 25-01.

After completion of this process, the machine goes into the sub code entry standby mode.

[Operation]

02

Main charger output (Grid
HIGH) (MHV(H) SET.)

[Function]
When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage
HIGH move.

After completion of this process, the machine goes into the sub code entry standby mode.

[Operation]

03

Main charger output (Grid
LOW) (MHV(L) SET.)

[Function]
When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage
LOW move.

After completion of this process, the machine goes into the sub code entry standby mode.

[Operation]

06

Transfer charger output
(THV SET.)

[Function]
When [ENTER/START] key is pressed, the transfer charger is outputted for 30sec.

After completion of this process, the machine goes into the sub code entry standby mode.

[Operation]

Main
code

Sub

code

Contents

Details of function/operation

1) Initial display (Basic display of copy)

READY TO COPY

100% A4 0

1) Initial display

2) After 10sec

07-08 W-UP C-MODE

0

07-08 W-UP C-MODE

10

1) Initial display

08-01 DVLP BIAS SET.

EXECUTING...

1) Initial display

08-02 MHV(H) SET.

EXECUTING...

1) Initial display

08-03 MHV(L) SET.

EXECUTING...

1) Initial display

08-03 THV SET.

EXECUTING...

Advertising