AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 18

46

19

Exposure mode setting (AE
MODE)

[Function]
<

γ

table setting>

When this test command is executed, the code number of the current set gamma table is displayed.
(Default: Japan -1/Ex Japan -2)
Enter the code number corresponding to the desired gamma table, and press [

/

] key to change

the mode and write into the EEPROM.

<AE operation mode>

When setting the

γ

table, press [

] key to change to the AE operation mode, and the current set code

number of the AE operation mode is displayed. (Default: 0)
Enter the code number corresponding to the desired AE operation mode and press [

/

] key to

change the mode and write into the EEPROM.

<PHOTO image process setting>

When [

] key is pressed in AE operation mode setting, the mode is changed to the PHOTO image

process setting and the code number of the current set PHOTO image process setting is displayed.
(Default: 0)
Enter the code number corresponding to the desired PHOTO image process setting and press [

/

]

key to change the mode and write into the EEPROM.

[Operation]

20

SPF exposure correction
(EXP.LEVEL SPF)

[Function]
Used to adjust the exposure correction amount in the SPF mode. The adjustment is made by adjust-
ing Vref voltage variation for the OC mode.

When this test command is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to save the setting and make a copy.

When the set value is increased, copy becomes darker. When the set value is decreased, copy
becomes lighter. (Adjustment range: 1 – 99)

[Operation]
The operation is similar to test command 46-01.

Main
code

Sub

code

Contents

Details of function/operation

Mode

Display item

Code number

Setting content

Remark

γ

GAMMA

1

Image quality priority mode

Japan default

2

Toner consumption priority mode

EX Japan default

AE

AE

0

Lead edge stop

Default

1

Real time process

PHOTO

PHOTO

1

Error diffusion process

Default

2

Dither process

1) Initial display

<

γ

table setting>

2) [

] Mode selection

2) [

] Mode selection

3) [10KEY] Value input

4) [ENTER/START] Save the

set value. The machine
goes to the sub code entry
standby mode.

46-19 AE MODE

GAMMA 2( 1-2)

46-19 AE MODE

AE 0( 0-1)

46-19 AE MODE

PHOTO 1( 1-2)

46-19 AE MODE

AE 1( 0-1)