Burkert Type 4040 Benutzerhandbuch

Seite 25

Advertising
background image

4040 - 23

english

Definitions and Abbreviations of Values Used

Abbrevi-
ation

Display
(6 charac-
ters maxi-
mum)

Description

In module

Meaning

Default value

Value
range

Unit

Recipe datum

Process datum

Parameter datum

Calibration datum

A

Pipe surface before and
after lock

AUTO conveyance
STOP without empty
run
STOP with empty run

Calculated from D

mm

t11

t11

Pause: remaining
conveying time without
empty run

STOP without empty
run

Medium is conveyed
using the last setting of
the conveying valve for
this period

60

1-255

s

yes

t15

t15

Pause: remaining
conveying time without
empty run

STOP with empty run

Medium is conveyed at
empty-run speed for this
period

60

1-255

s

yes

v

v

Actual speed at the
conveying valve

AUTO conveyance

STOP with empty run

Momentary speed from
calculation

0

0-40

m/s

yes

v0

v0

Target speed

AUTO conveyance
STOP with empty run

Target speed at end of
conveying line, internal
value for calculation

0

0-40

m/s

yes

v0ist

Actual speed at end of
conveying line

AUTO conveyance

STOP with empty run

Momentary speed from
calculation

0

0-40

m/s

yes

p

p

Conveying pressure

AUTO conveyance
STOP without empty
run
STOP with empty run

Pressure after
regulatory valve

0

0-10.00

bar

yes

pa

Absolute conveying
pressure

AUTO conveyance
STOP without empty
run
STOP with empty run

Absolute pressure after
regulatory valve

1

1-11.00

bar

yes

p1

p1

Main pressure

AUTO conveyance
STOP without empty
run
STOP with empty run

System's entrance
pressure

0

0-10.00

bar

yes

p1a

Absolute main pressure

AUTO conveyance
STOP without empty
run
STOP with empty run

Absolute entrance
pressure

1

1-11.00

bar

yes

QeffN

Effective air quantity at
end of conveying line
(standard)

AUTO conveyance

Air quantity at end of
conveying line

0

0-10000

Nm 3/h

yes

ActUal_
valve_lift

Actual_lift

Current setting of
conveying valve

AUTO conveyance
STOP without empty
run
STOP with empty run

for calculation of Q or v

0

0-100

%

yes

T

T

Display of actual tempe-
rature

AUTO conveyance
STOP without empty
run
STOP with empty run

Measured or manually
entered temperature,
especially for the display

0

0-160

°C

yes

Lock

Operating
hours

Lock's operating hours

AUTO conveyance

Current operating hours
(lock IN); save each
hour in EEPROM

0

0-65535

h

yes

O

PERATION