24 - 4040

english

Definitions and Abbreviations of the Values Used

Abbreviation

Display
(6 characters
maximum)

Description

In module

Meaning

Default value

Value
range

Unit

Recipe datum

Process datum

Parameter datum

Calibration datum

t1

t1

Pause: settling time after
start

AUTO conveyance

Time after vE has been
reached after start

15 10-100 s

yes

t2

t2

Time out: no conveying of
materials

AUTO conveyance

If pressure remains below
pmin for this period, the
system assumes that there
is no flow of materials

20 10-100 s

yes

t3

t3

Time out: system blocked
at lock
IN

AUTO conveyance

If pressure exceeds pmax
for this period, the system
assumes that the pipes are
blocked

10 5-100

s

yes

t4

t4

Pause: settling time at
lock

STOP due to blockage

AUTO conveyance

After this period, the lock is
opened again

10 5-100

s

yes

t5

t5

Time out: system blocked
at lock

STOP due to blockage

AUTO conveyance

If the system is blocked for
this period, there will be
an alarm

20 5-100

s

yes

t6

t6

Time out: check
Buffer FULL

AUTO conveyance

If the signal Buffer FULL
appears for this period,
Buffer FULL is accepted

10 5-100

s

yes

t7

t7

Pause: settling time for
lock

STOP because buffer
FULL

AUTO conveyance

After this period, the lock is
opened again

10 5-100

s

yes

t8

t8

Time out: system blocked
at lock

STOP because buffer
FULL

AUTO conveyance

If the buffer is full for this
period, there will be an
alarm

10 5-100

s

yes

t12

t12

Time out: system blocked
at lock

STOP

STOP without empty
run

Due to closed lock and
blockage

60 5-100

s

yes

t13

t13

Time out: no material

STOP without empty
run

If pressure remains under
pmin for this period, the
system assumes there is
no flow of materials

60 5-100

s

yes

t16

t16

Time out: system blocked
at lock

STOP

STOP with empty run

Due to closed lock and
blockage

60 5-100

s

yes

t17

t17

Time out: no material

STOP with empty run

If the pressure remains
below pmin for this period,
the system assumes there
is no flow of materials

60 5-100

s

yes

T2

Default_Temp Actual temperature (ma-

nual entry)

AUTO conveyance
STOP without empty
run
STOP with empty run

Manually entered value for
the calculation of Q or v
is necessary if there is no
measured value available

0

0-160

°C

yes

QLP

QLP

Leakage air quantity
(operations)

AUTO conveyance

Offset by lock leakage at
various pressures (con-
veying pressure)

0

0-3000 m3/h

yes

QLPN

QLPN

Leakage air quantity
(standard)

AUTO conveyance

Offset by lock leakage at
various pressures (con-
veying pressure)

0

0-3000 Nm3/h

O

PERATION