2. Safety / 3. Specifications

2.4.2 Explanation of symbols

Before mounting and commissioning the instrument, ensure

you read the operating instructions!

CE, Communauté Européenne

Instruments bearing this mark comply with the relevant

European directives.

3. Specifications

Attachable indicator

Display

Principle

7-segment LCD, 4-digit, character size 10 mm

Indication range

-1999 ... 9999

Accuracy

±0.2 % of the measuring span ±1 digit

Measuring rate

5 measurements/sec

Voltage supply

Electrical connection

To transmitters with 4 ... 20 mA output and

angular connector to DIN 175301-803 A

.

Power supply

Not required, since the attachable indicator is

powered by the 4 ... 20 mA loop

Voltage drop

approx. DC 2 V

Permitted current carrying

capacity

max. 40 mA

Case

Material

ABS, front window from polycarbonate

Ingress protection

IP 65 per EN 60529 / IEC 529

Dimensions

48.5 x 48.5 mm

Weight

approx. 80 g