Instructions for the installer, Connecting to the electrical supply, Terminal block – Zanussi ZYB 590 XL Benutzerhandbuch

Seite 36

Advertising
background image

36

Instructions for the Installer

Installation and connection must be
done in compliance with the
regulations in force. Any
interventions must be carried out
when the appliance is switched off.
Only accredited engineers may work
on the appliance.
The manufacturer disclaims any
liability if the safety measures are not
observed.

Connecting to the electrical supply

Before connecting to the electrical supply, please
make sure:
- The fuse and the domestic electrical installation

must be designed for the max. load of the
appliance (see rating plate).

- The domestic electrical installation must be

equipped with a proper earth connection in
accordance with the regulations in force.

- The socket or the multi-pole off switch must be

easy to access after the appliance has been
installed.

This appliance is supplied with a connection cable
incorporating a standard plug, suitable for the total
electric load shown on the rating plate. The plug is
to be inserted into a suitable wall socket. If you
require a direct connection to the electric network
(mains), it will be necessary to fit between the ap-
pliance and the mains an omnipole switch, with a
minimum gap between contacts of 3 mm, suitable
for the required load and in compliance with rules
in force. The green & yellow ground wire must not
be interrupted by the switch and

it should be 2-3

cm longer than the other cables. The supply cable
must in all cases be laid out in such a way as to
ensure that it does not reach at any given point a
temperature 50 °C higher than the ambient tem-
perature.

Suitable power supply cables are the following
types, considering the respective necessary sec-
tion of cable: H07 RN-F, H05 RN-F, H05 RR-F,
H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
After the connection has been carried out, the heat-
ing elements must be tested by being operated for
about 3 minutes.

Terminal block

The oven is fitted with an easily accessible terminal
block which is designed to operate with a single-
phase power supply of 230 V.

Letter L -

Live terminal

Letter N-

Neutral terminal

or E -

Earth terminal

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: