Diaphragm Pumps PJ19423-726

Use

Translation of Original Operating- and Installation Instructions, english, KNF PJ19423-726 02/13

4

2.3. Use in hazardous areas

In hazardous areas (zones), only operate pumps and motors of the
corresponding equipment category and temperature class.

The pumps have the following explosion protection marking:

Marking

Description

Symbol for explosion-proof pumps

II

Equipment group (see Section 2.4.1)

2 G

Equipment category (see Section 2.4.2)

c

Type of protection (see Section 2.4.5)

II B

Explosion group (see Section 2.4.4)

T4

Temperature class (see Section 2.4.3)

X

Additional conditions (see Section 2.4.6)

Tab. 2

The explosion protection marking is also applied at the following
location:

ƒ

Pump type plate

The pump drive motor must have at least the same explosion
protection rating as the pump.

Drive motor