Diaphragm Pumps PJ19423-726

Servicing

Translation of Original Operating- and Installation Instructions, english, KNF PJ19423-726 02/13

17

8. Servicing

8.1. Servicing schedule

WARNING

Danger of explosion due to wear!

Î

Have connecting rod bearing replaced by KNF

according to servicing schedule.

Î

Have motor bearings replaced by KNF according

to servicing schedule.

Component

Servcing interval

Pump

Regular inspection for external damage
or leaks

Molded diaphragm
and valve plates

Replace at the latest, when pump output
decreases

Connecting rod bear-
ing

Have it replaced after 17,000 operating
hours or 24 months at the latest

Motor bearings

Have them replaced after 17,000 operat-
ing hours or 24 months at the latest

Tab. 11

8.2. Cleaning

8.2.1. Flushing pump

WARNING

Danger of explosion when flushing pump
with air!
Î

In hazardous areas, or in cases when the pump

is used with explosive media, only have pump
flushed with inert gas by specially trained per-
sonnel.

Î

Flush the pump for several minutes with inert gas under at-

mospheric conditions before switching it off.

If there is no danger of explosion, air can also be used for

flushing.

8.2.2. Cleaning pump

WARNING

Danger of explosion from electrostatic
charging of components!
Î

Only clean pump with a damp cloth.

Î

Only clean the pump with a damp cloth and non-flammable

cleaning agents.

Î

If compressed air is available, blow out the components.