KNF Motor M 56 Ex

Installation and connection

Translation of orignal Operating and Installation Instructions, english, KNF 121220-121648 01/13

11

6. Installation and connection

Î

Only install and operate the motor under the operating pa-

rameters and conditions described in Chapter 4, Technical da-
ta, and Section 2.3, Use in hazardous areas.

Î

Observe the safety precautions (see Chapter 3).

6.1. Installation

Î

Before installation, store the motor at the installation location

for 3 hours to bring it up to room temperature.

WARNING

Danger of explosion from insufficient cooling

Î

Install the motor so that the motor fan can intake

sufficient cooling air.

Î

Ensure sufficient ventilation and heat dissipation

around the motor.

Î

Make sure that the installation location is dry and the motor is

protected against rain, splash, hose and drip water.

Î

Protect the motor from dust.

Î

Protect the motor from vibrations and jolts.

6.2. Electrical connection

DANGER

Extreme danger from electrical shock!

Î

Only have the motor connected by an authorized

specialist.

Î

Only have the motor connected when the power

supply is disconnected.

Î

The customary national and international regulations on the

set-up of electrical systems in potentially explosive atmos-
pheres must be observed.

Î

The motor may only be connected to the electrical supply, if it

is certain that it can be safely operated in the potentially explo-
sive atmosphere that is present.

Î

The general safety and commissioning notes apply to the

electrical wiring.

Î

Connection of the motor to the electrical supply must be car-

ried out by a person qualified to do so, who is authorized to
connect electrical equipment in hazardous environments.

Î

Area A per IEC 34-1 (voltage

± 5%, frequency ± 2%) must be

maintained so that the temperature is kept within the permissi-
ble limits. Exceptions are permitted only if they are indicated on
the motor output plate.

Î

Only electrical equipment that is absolutely necessary for

operating the motor should be located in the hazardous area.

Î

The installation, or additional measures, must protect the motor

against water as well as against electrical, chemical, thermal,

Cooling air supply

Installation location

General hints