M&C TechGroup MP47-Z_Ex Operator's manual Benutzerhandbuch

Seite 48

Advertising
background image

Diaphragm Pumps PJ19423-726

Servicing

Translation of Original Operating- and Installation Instructions, english, KNF PJ19423-726 02/13

20

2. Position the pump head on the housing A according to the felt-

tip pen marking.

3. Fit the 4 allen screws H and tighten them uniformly diagonally

until the disc springs R are flattened.

To prevent parts from warping, start by tightening each of the
screws half a turn alternately.

4. At the valve bodies F and G tighten each three allen screws D

carefully until resistance is noticeable.

5. Check the smooth movement of the pump by turning the

counterweight P.

6. Mount cover N with the four cheese head screws M.

7. Check and ensure the gas-tightness of the pump head and the

tubing:

WARNING

Hazard of explosion caused by leaks

Î

Before putting the pump into operation again,

check and ensure the gas-tightness of the pump
head and the tubing. Leakages may lead to ex-
plosion hazard!

Advertising