Diaphragm Pumps PJ19423-726

Installation and connection

Translation of Original Operating- and Installation Instructions, english, KNF PJ19423-726 02/13

13

6.2. Electrical connection

DANGER

Extreme danger from electrical shock!

Î

Only have the pump connected by an authorized

specialist.

Î

Only have the pump connected when the power

supply is disconnected.

WARNING

Danger of explosion from electrostatic charging!

Î

Connect the pump so that the danger of ignition

from electrostatic charging is prevented.

Î

Carefully ground the pump.

Î

Observe the drive-motor operating- and installation instruc-

tions.

Î

Only position the electrical equipment in hazardous areas

which is required there for pump operation.

Î

Take lightning protection measures.

Drive motor

Hazardous

areas

Advertising