Troubleshooting – M&C TechGroup MP47-Z_Ex Operator's manual Benutzerhandbuch

Seite 50

Advertising
background image

Diaphragm Pumps PJ19423-726

Troubleshooting

Translation of Original Operating- and Installation Instructions, english, KNF PJ19423-726 02/13

22

9. Troubleshooting

DANGER

Extreme danger from electrical shock!

Î

Disconnect the pump power supply before working

on the pump.

Î

Make sure the pump is de-energized and secure.

1. Check the pump (see Tab. 14 and 15).

2. Also see the drive-motor operating- and installation instructions

for troubleshooting.

Pump does not transfer

Cause

Fault remedy

Connections or lines blocked.

Î

Check connections and lines.

Î

Remove blockage.

External valve is closed or filter
is clogged.

Î

Check external valves and filters.

Condensate has collected in
pump head.

Î

Flush pump (see Section 8.2.1).

Î

Install pump at highest point in system.

Diaphragm or valve plates are
worn.

Î

Replace diaphragm and valve plates (see Section 8.3).

Tab. 14

Flow rate, pressure or vacuum too low

The pump does not achieve the output specified in the Technical data or the data sheet.
Cause

Fault remedy

Condensate has collected in
pump head.

Î

Flush pump (see Section 8.2.1).

Î

Install pump at highest point in system.

There is gauge pressure on
pressure side and at the same
time vacuum or a pressure
above atmospheric pressure on
suction side.

Î

Change the pressure conditions.

Pneumatic lines or connection
parts have an insufficient cross
section or are throttled.

Î

Disconnect pump from system to determine output values.

Î

Eliminate throttling (e.g. valve) if necessary.

Î

Use lines or connection parts with larger cross section if

necessary.

Leaks occur on connections,
lines or pump head.

Î

Eliminate leaks.

Connections or lines completely
or partially jammed.

Î

Check connections and lines.

Î

Remove the jamming parts and particles.

Head parts are soiled.

Î

Clean head components.

Diaphragm or valve plates are
worn.

Î

Replace diaphragm and valve plates

(see Section 8.3).

Tab. 15

Advertising